Power draw, and what each watt is measured at
Power is the one specification that is almost never comparable between datasheets, because it depends on the update rate, the range setting and the supply voltage. This table lists the published average for 22 modules, the power per metre of published range, and the exact sentence the figure came from — so you can see whether two numbers were measured the same way before you compare them.
How to read it
- Power per metre (mW/m) = average power ÷ published range. It is a rough efficiency index, nothing more. A module drawing 2.5 W to reach 4 km scores better than one drawing 0.9 W to reach 300 m, even though the second uses less power in absolute terms.
- The condition column is the point. "≤0.9 W at 1 Hz, <1.5 W at 10 Hz" and "≤2.5 W at 10 Hz" are not the same measurement. Where a datasheet states a rate, it is printed here verbatim.
- Standby is separate. Several modules publish a standby figure below 10 mW; that number decides battery life in a duty-cycled product far more than the operating figure does. It is not in this table — ask for it.
Where the numbers come from
| Model | Band | Published range | Average power | Power per metre | Mass | Published power statement (verbatim) |
|---|---|---|---|---|---|---|
| LRF0105C | 1535 nm | 3 km | 0.8 W | 0.27 mW/m | 29 g | Average ≤0.8 W; peak ≤1.5 W; standby ≤1 mW |
| LRF0305C | 1535 nm | 4 km | 0.9 W | 0.23 mW/m | 14 g | At 5 V: operating ≤0.9 W at 1 Hz and <1.5 W at 10 Hz; peak <3 W Standby ≤10 mW with Power_on low; ≤0.8 W with Power_on high. |
| LRF0306C | 1535 nm | 4 km | 0.9 W | 0.23 mW/m | 14 g | At 5 V: operating ≤0.9 W at 1 Hz and <1.1 W at 3 Hz; peak ≤3 W Standby ≤10 mW with Power_on low; ≤0.8 W with Power_on high. |
| LR1000E2 | 905 nm | 1 km | 1 W | 1.00 mW/m | 10 g | ≤ 1 W |
| LR1000E4 | 905 nm | 1 km | 1 W | 1.00 mW/m | 10 g | ≤ 1 W |
| LRF0310C | 1535 nm | 3 km | 1.5 W | 0.50 mW/m | 32 g | Average ≤1.5 W at 1 Hz; peak ≤7 W at 12 V; standby ≤0.6 W |
| LRF0609C | 1535 nm | 6 km | 1.5 W | 0.25 mW/m | 62 g | Average ≤1.5 W; standby ≤0.3 W; operating condition not stated |
| LRF1200A1 | 905 nm | 1.2 km | 1.5 W | 1.25 mW/m | 18 g | ≤1.5 W |
| LRF3000A1 | 905 nm | 3 km | 1.8 W | 0.60 mW/m | 12 g | ≤1.8 W at +25 °C; ≤1.6 W at -20 °C — +3.3 V input. These entries do not extend the operating-temperature range. |
| LRF0815C | 1535 nm | 8 km | 2 W | 0.25 mW/m | 175 g | Average ≤2 W (condition not stated); peak ≤3 W at 10 Hz; standby ≤1.2 W |
| LRF1017C | 1.54 µm | 10 km | 2 W | 0.20 mW/m | 275 g | Average ≤2 W; peak ≤3 W at 10 Hz; standby ≤1.2 W |
| LRF1221C | 1.54 µm | 12 km | 2 W | 0.17 mW/m | 275 g | Average ≤2 W; peak ≤3 W at 10 Hz; standby ≤1.2 W |
| LRF1222C | 1.54 µm | 12 km | 2 W | 0.17 mW/m | 335 g | Average ≤2 W; peak ≤3 W at 10 Hz; standby ≤1.2 W |
| LRF1525C | 1.54 µm | 15 km | 2 W | 0.13 mW/m | 400 g | Average ≤2 W; peak ≤3 W; standby ≤1.2 W; peak-power test condition not stated |
| LRF1829C | 1535 nm | 23 km | 2 W | 0.09 mW/m | 400 g | Average ≤2 W; peak ≤3 W; standby ≤1.2 W; peak-power test condition not stated |
| LRF1830C | 1.54 µm | 23 km | 2 W | 0.09 mW/m | 400 g | Average ≤2 W; peak ≤3 W; standby ≤1.2 W; peak-power test condition not stated |
| LRF1831C | 1535 nm | 12 km | 2 W | 0.17 mW/m | 410 g | Average ≤2 W; peak ≤3 W; standby ≤1.2 W; peak-power test condition not stated |
| LRF0405C | 1535 nm | 4 km | 2.5 W | 0.62 mW/m | 32 g | Average ≤2.5 W at 10 Hz; peak ≤7 W at 12 V. The 12 V condition conflicts with the 3-5 V specification row. |
| LRF0610C | 1535 nm | 6 km | 2.5 W | 0.42 mW/m | 90 g | Average ≤2.5 W at 10 Hz; peak ≤7 W at 12 V; standby ≤1 mW |
| LRF0612C | 1535 nm | 6 km | 4 W | 0.67 mW/m | 58 g | Average ≤4 W (source leaves the '@' condition blank); peak ≤14 W at 12 V; standby ≤1 mW |
| LRF0816C | 1535 nm | 8 km | 4 W | 0.50 mW/m | 58 g | Average ≤4 W (source leaves the '@' condition blank); peak ≤14 W at 12 V; standby ≤1 mW |
| LRF0818C | 1535 nm | 8 km | 4 W | 0.50 mW/m | 65 g | Operating ≤4 W; peak ≤14 W at 12 V; standby ≤1 mW |
CC BY 4.0 — cite as ERDI LRF power table, 2026-11-25, https://specs.erdilrf.com/data/power.
If a module is not in this table, it is because its datasheet does not publish a power figure at all, not because