Power draw, and what each watt is measured at

Power is the one specification that is almost never comparable between datasheets, because it depends on the update rate, the range setting and the supply voltage. This table lists the published average for 22 modules, the power per metre of published range, and the exact sentence the figure came from — so you can see whether two numbers were measured the same way before you compare them.

How to read it

Where the numbers come from

Every row is transcribed from the published specification of that module. Nothing is estimated. Machine-readable dataset with the other columns: CSV · JSON.

ModelBandPublished rangeAverage power Power per metreMassPublished power statement (verbatim)
LRF0105C1535 nm3 km0.8 W0.27 mW/m29 gAverage ≤0.8 W; peak ≤1.5 W; standby ≤1 mW
LRF0305C1535 nm4 km0.9 W0.23 mW/m14 gAt 5 V: operating ≤0.9 W at 1 Hz and <1.5 W at 10 Hz; peak <3 W Standby ≤10 mW with Power_on low; ≤0.8 W with Power_on high.
LRF0306C1535 nm4 km0.9 W0.23 mW/m14 gAt 5 V: operating ≤0.9 W at 1 Hz and <1.1 W at 3 Hz; peak ≤3 W Standby ≤10 mW with Power_on low; ≤0.8 W with Power_on high.
LR1000E2905 nm1 km1 W1.00 mW/m10 g≤ 1 W
LR1000E4905 nm1 km1 W1.00 mW/m10 g≤ 1 W
LRF0310C1535 nm3 km1.5 W0.50 mW/m32 gAverage ≤1.5 W at 1 Hz; peak ≤7 W at 12 V; standby ≤0.6 W
LRF0609C1535 nm6 km1.5 W0.25 mW/m62 gAverage ≤1.5 W; standby ≤0.3 W; operating condition not stated
LRF1200A1905 nm1.2 km1.5 W1.25 mW/m18 g≤1.5 W
LRF3000A1905 nm3 km1.8 W0.60 mW/m12 g≤1.8 W at +25 °C; ≤1.6 W at -20 °C — +3.3 V input. These entries do not extend the operating-temperature range.
LRF0815C1535 nm8 km2 W0.25 mW/m175 gAverage ≤2 W (condition not stated); peak ≤3 W at 10 Hz; standby ≤1.2 W
LRF1017C1.54 µm10 km2 W0.20 mW/m275 gAverage ≤2 W; peak ≤3 W at 10 Hz; standby ≤1.2 W
LRF1221C1.54 µm12 km2 W0.17 mW/m275 gAverage ≤2 W; peak ≤3 W at 10 Hz; standby ≤1.2 W
LRF1222C1.54 µm12 km2 W0.17 mW/m335 gAverage ≤2 W; peak ≤3 W at 10 Hz; standby ≤1.2 W
LRF1525C1.54 µm15 km2 W0.13 mW/m400 gAverage ≤2 W; peak ≤3 W; standby ≤1.2 W; peak-power test condition not stated
LRF1829C1535 nm23 km2 W0.09 mW/m400 gAverage ≤2 W; peak ≤3 W; standby ≤1.2 W; peak-power test condition not stated
LRF1830C1.54 µm23 km2 W0.09 mW/m400 gAverage ≤2 W; peak ≤3 W; standby ≤1.2 W; peak-power test condition not stated
LRF1831C1535 nm12 km2 W0.17 mW/m410 gAverage ≤2 W; peak ≤3 W; standby ≤1.2 W; peak-power test condition not stated
LRF0405C1535 nm4 km2.5 W0.62 mW/m32 gAverage ≤2.5 W at 10 Hz; peak ≤7 W at 12 V. The 12 V condition conflicts with the 3-5 V specification row.
LRF0610C1535 nm6 km2.5 W0.42 mW/m90 gAverage ≤2.5 W at 10 Hz; peak ≤7 W at 12 V; standby ≤1 mW
LRF0612C1535 nm6 km4 W0.67 mW/m58 gAverage ≤4 W (source leaves the '@' condition blank); peak ≤14 W at 12 V; standby ≤1 mW
LRF0816C1535 nm8 km4 W0.50 mW/m58 gAverage ≤4 W (source leaves the '@' condition blank); peak ≤14 W at 12 V; standby ≤1 mW
LRF0818C1535 nm8 km4 W0.50 mW/m65 gOperating ≤4 W; peak ≤14 W at 12 V; standby ≤1 mW

CC BY 4.0 — cite as ERDI LRF power table, 2026-11-25, https://specs.erdilrf.com/data/power. If a module is not in this table, it is because its datasheet does not publish a power figure at all, not because the figure was withheld.