Component datasheet · ERDI TECH LTD · laser rangefinder modules and eye-safe laser sources
Model
SPD1200N3
Family
905nm
Wavelength
905 ± 5 nm — Ranging emitter; not the indication-laser wavelength
Measuring range (with the condition it was measured under)
3-1000 m — Building target; visibility ≥10 km; humidity ≤60%
Accuracy / resolution
±0.5 m at d ≤100 m; ±(0.5 m + 0.00075d) for 100 m < d <1000 m — d is distance in meters; no additional endpoint accuracy inferred
Update rate
2.5-15 Hz — Varies with distance; not the laser pulse repetition rate
Interface
UART, 3.3 V TTL; customizable
Supply
DC 3.3-5 V — Does not imply 5 V tolerance on serial inputs Average power consumption ≤0.5 W
Power
—
Mass
≤6 g
Dimensions
—
Operating temperature
-20 to +60 °C Nominal body dimensions / material 14 × 18 × 22.3 mm; rectangular; 6061 aluminum alloy — Use the controlled mechanical drawing
Laser class
—
Pulse energy
—
How to read the range figure. A range number without its target size, reflectance and
visibility is not comparable to anything. The figure above carries the manufacturer's own condition, quoted
verbatim. If you need a different target or a different visibility, ask — the usable range changes, and we
would rather state both than let you discover it in the field.
What is not in this sheet. Pinout, command frames and the protocol document are supplied
with the units, matched to your firmware revision. We do not publish them here because frames differ between
revisions and a generic frame does nothing on your bench.