Component datasheet · ERDI TECH LTD · laser rangefinder modules and eye-safe laser sources
Model
SPD1200N0
Family
905nm
Wavelength
905 nm ±5 nm Beam divergence <4.5 mrad
Measuring range (with the condition it was measured under)
0.2-1200 m; maximum 1500 m at night — strong sunlight or low visibility may reduce range
Accuracy / resolution
±0.3 m (D ≤100 m); ±0.3 m + D × 0.7‰ (100 m < D <1200 m) Measurement frequency 2-15 Hz or 4-15 Hz, adaptive — both alternatives appear in th
Update rate
—
Interface
UART-TTL (customizable)
Supply
3.3-5 V Operating power Average ≈0.45 W; maximum ≤0.75 W
Power
—
Mass
≈5 g Protection rating IP67 inside lens chamber — Source-stated classification or rating; not independently certified by this page
Dimensions
Diameter 15.7 × 21.3 mm (round, with sealing groove)
Operating temperature
-20°C to +60°C
Laser class
—
Pulse energy
—
How to read the range figure. A range number without its target size, reflectance and
visibility is not comparable to anything. The figure above carries the manufacturer's own condition, quoted
verbatim. If you need a different target or a different visibility, ask — the usable range changes, and we
would rather state both than let you discover it in the field.
What is not in this sheet. Pinout, command frames and the protocol document are supplied
with the units, matched to your firmware revision. We do not publish them here because frames differ between
revisions and a generic frame does nothing on your bench.